Lennox 34M76 Pressure Switch dirty evaporator coil
Baker’s notes & crumb story
Description
dirty evaporator coil
The manual reset feature is essential for diagnostic purposes
the bimetal disc triggers a circuit break to prevent heat exchanger fracturing or component damage
Only if you are performing a remote mounting installation
Lennox 34M76 Pressure Switch dirty evaporator coilThe Lennox 34M76 Pressure Switch is a critical safety component designed for high efficiency condensing gas furnaces. Engineered with an actuation set point of . 86" WC (Water Column) and a reset point of 1. 01" WC, this Single Pole Single Throw (SPST) switch ensures the inducer motor establishes a proper vacuum before the ignition sequence begins. Designed for a 1 4" barb connection, it provides a reliable pneumatic seal to prevent the furnace from